ST program
■
Downloading IO parameters
The IO parameters of the high-speed counter function are downloaded to the GM1 controller
together with user programs.
When an operation ready request is issued in RUN mode and the operation ready status bit
turns ON, each function of the high-speed counter function is enabled.
■
Behaviors when operation ready request program is executed
When the operation ready request program is executed and each behavior set in the GM1
controller becomes executable, the operation ready status bit turns ON.
Behaviors of operation ready request bit
(Note 1)
Ensure that the operation ready request bit remains ON when the high-speed counter is used.
● If the default value or preset value is out of range, the operation ready status bit will not turn
ON.
12.6 High-speed Counter Function
12-30 WUME-GM1RTXOP-01