ST program
Count value when the power is turned on
When the power is turned on, the count value is "0".
Changing the current count value
The current count value can be changed to any value as necessary.
Set a value in the temporary current value channel and turn ON the current value change
request bit.
Example: A program to change the current value of CH0 to 1000000
Count values cannot be written directly to the count value channel (Ch*_CountValue).
Changing the preset value
The preset value can be changed to any value as necessary.
Set a value in the temporary preset value channel and turn ON the preset value change
request bit.
12.6 High-speed Counter Function
12-40 WUME-GM1RTXOP-01