Default
10 s
Value Range
0–60 s
Maintenance Console Location
24.4 UM Configuration
—[5-4] System Parameters—Parameters
Maximum Continuous Tone Time (0-60 s)
Specifies
the length of time the system waits when a continuous tone is detected before it disconnects the call.
Default
6 s
Value Range
0–60 s
Maintenance Console Location
24.4 UM Configuration—[5-4] System Parameters—Parameters
Maximum Cyclic Tone Time (0-60 s)
Specifies the length of time the system waits when a cyclic tone is detected before it disconnects the call.
Default
6 s
Value Range
0–60 s
Maintenance Console Location
24.4 UM Configuration
—[5-4] System Parameters—Parameters
Maximum Call Duration (0-60 min)
Specifies the maximum duration of calls. If the system detects no DTMF signals for the specified amount of
time, it terminates the call. Calls will not be terminated while playing or recording messages. If this setting is
set to "0", calls will not be terminated.
Default
10 min
Value Range
0–60 min
Document Version 2016-03 PC Programming Manual 1071
24.4 UM Configuration—[5-4] System Parameters—Parameters