Maintenance Console Location
24.4 UM Configuration—[5-4] System Parameters—Parameters
Transfer to Outside
These parameters determine how the system will transfer calls to a CO line via the following features: Call
Transfer Service, Custom Service, Personal Custom Service, Caller ID Callback, Call-through Service.
Outside Transfer Sequence—Call Transfer to Outside Sequence (Up to 16
digits / [0-9 * # D F R T , ; N])
Specifies the sequence the system uses to transfer calls to CO lines.
Default
FND
Value Range
Max. 16 digits consisting of 0–9,
, # and special codes
D: Disconnecting
F: Flash (Recall)
R: Ringback Tone Detection
T: Dial Tone Detection
, : Dial Pause for 1 s (default)
; : Dial Pause for 3 s (default)
N: Telephone Number Dialing
0–9, , #: Dial Code
Maintenance Console Location
24.4 UM Configuration
—[5-4] System Parameters—Parameters
Feature Manual References
20.1.16 Unified Messaging—Call Transfer to Outside
Outside Transfer Sequence—EFA Transfer Sequence (Up to 16 digits / [0-9 * #
D F R T , ; N A])
Specifies the sequence the system uses to transfer calls to CO lines using EFA
(External Feature Access).
This setting should match the settings of the PBX.
Default
FATN
Value Range
Max. 16 digits consisting of 0–9,
, # and special codes
D: Disconnecting
F: Flash (Recall)
R: Ringback Tone Detection
T: Dial Tone Detection
, : Dial Pause for 1 s (default)
; : Dial Pause for 3 s (default)
1072 PC Programming Manual Document Version 2016-03
24.4 UM Configuration—[5-4] System Parameters—Parameters