Maintenance Console Location
9.6 PBX Configuration—[1-1] Configuration—Slot—UM Card Property
CNG Signal Effective Detection Width 2 (OFF)
Specifies the length of time that the PBX waits until another CNG signal is detected.
Default
3000 ms
Value Range
20–5000 ms
Maintenance Console Location
9.6 PBX Configuration—[1-1] Configuration
—Slot—UM Card Property
CNG Signal Fixation Detection Counter
Specifies the number of times the CNG signal must be detected before the PBX proceeds the fax operation.
Default
2
Value Range
1–3
Maintenance Console Location
9.6 PBX Configuration—[1-1] Configuration
—Slot—UM Card Property
CNG Signal Fixation Detection Pattern
Specifies whether or not the Unified Messaging system will respond to CNG signals.
Default
ON
Value Range
OFF, ON
Maintenance Console Location
9.6 PBX Configuration—[1-1] Configuration
—Slot—UM Card Property
Document Version 2016-03 PC Programming Manual 285
9.6 PBX Configuration—[1-1] Configuration—Slot—UM Card Property