EasyManua.ls Logo

Panasonic KX-NS1000 - 3.2.2.34 Two-way Record;Two-way Transfer

Panasonic KX-NS1000
1294 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Value Range
From Header, P-Preferred-Identity Header
Maintenance Console Location
9.11 PBX Configuration
—[1-1] Configuration—Slot—V-SIPGW—Port Property
From Header—User Part
Specifies the value to be stored in the username part of the SIP
-URI of the From header.
Default
User Name
Value Range
User Name, Authentication ID, PBX-CLIP
Maintenance Console Location
9.11 PBX Configuration—[1-1] Configuration—Slot—V-SIPGW—Port Property
From Header—SIP-URI
Specifies the complete SIP-URI address of the From header. The configuration in From Header—User Part
will be invalid if this parameter is set.
Default
Not stored
Value Range
Max. 100 characters
Maintenance Console Location
9.11 PBX Configuration
—[1-1] Configuration—Slot—V-SIPGW—Port Property
P-Preferred-Identity Header—User Part
Specifies the value to be stored in the username part of the SIP
-URI of the P-Preferred-Identity header.
Default
User Name
Value Range
User Name, Authentication ID, PBX-CLIP
Maintenance Console Location
9.11 PBX Configuration—[1-1] Configuration—Slot—V-SIPGW—Port Property
Document Version 2016-03 PC Programming Manual 313
9.11 PBX Configuration—[1-1] Configuration—Slot—V-SIPGW—Port Property

Table of Contents

Other manuals for Panasonic KX-NS1000

Related product manuals