Maintenance Console Location
9.12 PBX Configuration—[1-1] Configuration—Slot—V-IPGW16—Shelf Property
T319
Specifies the maximum time that the PBX waits for a reply after sending the Suspend message.
Default
0
Value Range
0–600 ´ 100 ms
Maintenance Console Location
9.12 PBX Configuration
—[1-1] Configuration—Slot—V-IPGW16—Shelf Property
T322
Specifies the maximum time that the PBX waits for a reply after sending the Status enquiry message.
Default
40
Value Range
0–600 ´ 100 ms
Maintenance Console Location
9.12 PBX Configuration
—[1-1] Configuration—Slot—V-IPGW16—Shelf Property
T3D3
Specifies the length of time after which the PBX tries to establish L2 in
"Permanent" mode.
Default
50
Value Range
0–3000 ´ 100 ms
Maintenance Console Location
9.12 PBX Configuration—[1-1] Configuration—Slot—V-IPGW16—Shelf Property
T3D9
Specifies the length of time after which the PBX tries to disconnect L2 in
"Call by Call" mode.
Default
200
348 PC Programming Manual Document Version 2016-03