T310
Specifies the maximum time that the PBX waits for a continuance message after receiving the Incoming Call
Proceeding message.
Default
1000
Value Range
0–3000 ´ 100 ms
Maintenance Console Location
9.12 PBX Configuration
—[1-1] Configuration—Slot—V-IPGW16—Shelf Property
T313
Specifies the maximum time that the PBX waits for a reply after sending the Connect message.
Default
60
Value Range
0–600 ´ 100 ms
Maintenance Console Location
9.12 PBX Configuration
—[1-1] Configuration—Slot—V-IPGW16—Shelf Property
T316
Specifies the maximum time that the PBX waits for a reply after sending the Restart message.
Default
0
Value Range
0–3000 ´ 100 ms
Maintenance Console Location
9.12 PBX Configuration
—[1-1] Configuration—Slot—V-IPGW16—Shelf Property
T318
Specifies the maximum time that the PBX waits for a reply after sending the Resume message.
Default
0
Value Range
0–600 ´ 100 ms
Document Version 2016-03 PC Programming Manual 347