ISDN CO / QSIG Master / QSIG Slave—T301
Specifies the maximum time that the PBX waits for a reply after making a call to ISDN.
Default
0
Value Range
0–18000 ´ 100 ms
Maintenance Console Location
9.26 PBX Configuration
—[1-1] Configuration—Slot—Card Property - PRI type
ISDN CO / QSIG Master / QSIG Slave—T302
Specifies the maximum time allowed between each digit on an incoming call. Applies to overlap receiving.
Default
150
Value Range
0–600 ´ 100 ms
Maintenance Console Location
9.26 PBX Configuration
—[1-1] Configuration—Slot—Card Property - PRI type
ISDN CO / QSIG Master / QSIG Slave—T303
Specifies
the maximum time that the PBX waits for a reply after sending the SETUP (call setting) message to
ISDN.
Default
40
Value Range
0–600 ´ 100 ms
Maintenance Console Location
9.26 PBX Configuration—[1-1] Configuration—Slot—Card Property - PRI type
ISDN CO / QSIG Master / QSIG Slave—T304
Specifies the maximum time allowed between each digit on an outgoing call. Applies to overlap sending.
Default
300
Value Range
0–3000 ´ 100 ms
442 PC Programming Manual Document Version 2016-03
9.26 PBX Configuration—[1-1] Configuration—Slot—Card Property - PRI type

Table of Contents