VTrak M610i, M310i, M210i Product Manual
94
Group Rounding – Uses an algorithm to determine how much to
truncate. Results in the maximum amount of usable drive capacity.
Table Rounding – Applies a predefined table to determine how much to
truncate.
Enter a time interval (1 to 12 seconds) in the Write Back Cache Flush
Interval field.
For more information, see “Cache Policy” on page 232.
Enter a time interval (15 to 255 seconds) in the Enclosure Polling
Interval field.
Check the Adaptive Writeback Cache box to enable the Adaptive
Writeback Cache feature.
For more information, see “Adaptive Writeback Cache” on page 232.
6. Click the Submit button.