VTrak M610i, M310i, M210i Product Manual
68
• Max outstanding R2T – Sets the maximum number of outstanding ready to
transfer PDUs (a number)
• Maximum burst length – Maximum length of a solicited data sequence
128 KB to 16,776,704 bytes (16 MB - 512 KB)
• Maximum number of connections – Maximum number of connections
supported
• Default time to wait – After a dropped connection, the number of seconds to
wait before attempting to reconnect
• Default time to retain – Number of seconds after time to wait (above) before
reassigning outstanding commands
• Error recovery level – Error recovery level supported
• Initial R2T – Allows initiator to begin sending data to a target without
receiving a ready to transfer command
• Header Digest – Enables the use of Header Digest (CRC). See note below
• Data Digest – Enables the use of a Data Digest (CRC). See note below
• Data PDU in order – Enables placement of data in PDU order
• Data sequence in order – Enables placement of data in sequence order
• Uni-directional CHAP Authentication – Enables Challenge Handshake
Authentication Protocol
• Bi-directional CHAP Authentication – Enables bi-directional and uni-
directional CHAP authentication
Making Node Settings
The settings made here apply to both iSCSI data ports.
To make iSCSI data port settings:
1. Click the Subsystem icon in Tree View.
2. Click the Administrative Tools icon.
3. Click the iSCSI Management icon.
4. Click the iSCSI Node 1 link in Management View.
5. Optional. Type an alias in the Alias field.
Maximum of 32 characters. Use letters, numbers, space between words,
and underscore. An alias is not required.
6. Enter the values in the fields as required.
7. Check the boxes to enable features as required.
8. Click the Submit button.