Chapter 6: Maintenance
203
1. From the Main Menu, highlight Additional Info and Management, and press
Enter.
2. Highlight Shutdown or Restart and press Enter.
3. Press the spacebar to display Restart then press Enter.
A warning message appears.
4. Press Y to continue.
The screen will go blank.
5. Wait for two to three minutes.
6. Re-establish your Telnet connection to the VTrak CLU.
If you cannot re-establish a connection, wait 30 seconds, then try again.
Restarting Subsystem over a Serial Connection
To restart the VTrak subsystem on a serial connection:
1. From the Main Menu, highlight Additional Info and Management, and press
Enter.
2. Highlight Shutdown or Restart and press Enter.
3. Press the spacebar to display Restart then press Enter.
A warning message appears.
4. Press Y to continue.
The screen will display shutdown and startup functions.
5. When the
Login: prompt appears, log into the CLU again.
Warning
Do not restart the VTrak during a firmware upgrade procedure.
Wait until the upgrade is one and you are prompted to restart.