Chapter 4: Management with WebPAM PROe
117
After Transition is completed, refresh the screen. The revertible spare drive will
be listed under the Spare Drives icon and the disk array’s operational status will
show OK.
To set Transition priority, see “Making Background Activity Settings” on page 51.
Preparing a Disk Array for Transport
Transport is the action of moving the physical drives of a disk array:
• To different slots in the same VTrak enclosure
• From one VTrak enclosure to another
To prepare a disk array for transport:
1. Click the Subsystem icon in Tree View.
2. Click the Disk Arrays icon.
3. Click the Disk Array icon.
4. Click the Transport tab in Management View.
5. Click the Submit button.
6. In the confirmation box, type the word confirm in the field provided.
7. Click the OK button.
8. After the Transition is complete, move the physical drives comprising the
disk array to their new locations.
9. Click the Refresh button in your Browser.
The drives appear in their new locations and disk array status displays OK.
Important
Before you can use this feature:
• There must be a dedicated spare disk drive assigned to this
disk array.
• The disk array’s Operational Status must be OK.