VTrak M610i, M310i, M210i Product Manual
264
PSU Fans
PSU fan has turned on. Normal.
PSU fan has turned off. Verify that the power supply is turned on. If the fan
still does not turn, replace the power supply. See
page 204.
PSU fan speed increased. Check the VTrak for overheating. See page 275.
PSU fan speed
decreased.
Temporary overheat condition was corrected.
PSU fan is malfunctioning Replace the power supply. See page 204.
PSU fan is functioning
normally
Normal.
PSU fan status is
unknown.
Check for airflow out of the power supply. If there is
none, check for proper installation and turn the power
supply on.
RAID Level Migration
RAID Level migration is
started
Result of settings or user action. Normal.
RAID Level migration is
completed
Normal.
RAID Level migration is
paused
Migration paused because of user intervention,
schedule or a higher priority background activity.
RAID Level migration is
resumed
Migration has resumed again after a pause.
RAID Level migration is
stopped
Migration stopped because of user intervention,
schedule or the logical drive was deleted or went
critical or offline.
RAID Level migration has
encountered a physical
disk error
Bad block found on a disk drive. Migration will finish.
Check the disk drive check table after migration and
replace disk drive as needed. See page 123.
RAID Level migration is
aborted due to an internal
error.
System resources are low. Reduce system load or
restart the VTrak. See page 90.
RAID Level migration is
queued
Migration has been set manually or by schedule.
Reported Event Corrective Action