CALCulate<n>:SNOise<s>:AOFF
This command turns all spot noise information off (custom and 10
x
information). It also
turns user defined spot noise markers off.
Suffix:
<n>
.
irrelevant
<s> irrelevant
Example: //Turn off all spot noise information
CALC:SNO:AOFF
Usage: Event
CALCulate<n>:SNOise<s>:STATe <State>
This command turns a custom spot noise position on and off.
Suffix:
<n>
.
irrelevant
<s> Spot noise marker
Parameters:
<State> ON | OFF | 1 | 0
*RST: All ON
Example: See CALCulate<n>:SNOise<s>[:TRACe<t>]:
USERdefined[:STATe].
CALCulate<n>:SNOise<s>:X <Frequency>...
This command defines the horizontal position of a custom spot noise position. The
position is changed in all windows.
Suffix:
<n>
.
irrelevant
<s> Spot noise marker
Parameters:
<Frequency> For minimum and maximum offsets, refer to the data sheet.
The default values are the decade edges (1 kHz, 10 kHz etc.)
Default unit: Hz
Example: See CALCulate<n>:SNOise<s>[:TRACe<t>]:
USERdefined[:STATe].
CALCulate<n>:SNOise<s>[:TRACe<t>]:DECades:X?
This command queries the horizontal position of the 10
x
offset frequency spot noise
information.
Common Measurement Settings