Remote Control
R&S
®
FSPN
400User Manual 1179.4363.02 ─ 01
Suffix:
<n>
.
irrelevant
Parameters:
<State> ON | OFF | 1 | 0
*RST: 0
Example:
CALC1:FREQ:DEV:STAT OFF
CALCulate<n>:FREQuency:DEViation:DIAGram <Diagram>
This command selects the diagram for frequency deviation calculation.
Suffix:
<n>
.
irrelevant
Parameters:
<Diagram> Number of the diagram
Example:
CALC:FREQ:DEV:DIAG 1
CALCulate<n>:FREQuency:DEViation:TRACe <Trace>
This command selects the trace for frequency deviation calculation.
Suffix:
<n>
.
irrelevant
Parameters:
<Trace> TRACe1 | TRACe2 | TRACe3 | TRACe4 | TRACe5 | TRACe6
Example:
CALC:FREQ:DEV:TRAC Trace1
CALCulate<n>:FREQuency:DEViation:STARt <Range>
This command defines the start frequency of frequency deviation measurement.
Suffix:
<n>
.
irrelevant
Parameters:
<Range> Default unit: s
Example:
CALC1:FREQ:DEV:STAR 100
CALCulate<n>:FREQuency:DEViation:STOP <Range>
This command defines the stop frequency of frequency deviation measurement.
Suffix:
<n>
.
irrelevant
Parameters:
<Range> Default unit: s
Common Measurement Settings