Remote Control
R&S
®
FSPN
431User Manual 1179.4363.02 ─ 01
CALCulate<n>:MARKer<m>:LINK <State>
This command defines whether all markers within the selected result display are
linked. If enabled, and you move one marker along the x-axis, all other markers in the
display are moved to the same x-axis position.
Suffix:
<m>
.
irrelevant
<n> Window
Parameters:
<State> ON | OFF | 1 | 0
*RST: 0
Example:
CALC2:MARK:LINK ON
Manual operation: See "Linked Markers" on page 171
11.7.4.3 Marker Search
CALCulate<n>:MARKer<m>:PEXCursion.........................................................................431
CALCulate<n>:MARKer<m>:FUNCtion:SPTRacking:RANGe............................................. 431
CALCulate<n>:MARKer<m>:FUNCtion:SPTRacking[:STATe]............................................. 432
CALCulate<n>:MARKer<m>:PEXCursion <Excursion>
The peak excursion sets the requirements for a peak to be detected during a peak
search.
The unit depends on the measurement.
Suffix:
<n>
.
<m> irrelevant
Example:
CALC:MARK:PEXC 10dB
Defines peak excursion as 10 dB.
Manual operation: See " Peak Excursion " on page 172
CALCulate<n>:MARKer<m>:FUNCtion:SPTRacking:RANGe <Range>
This command defines the frequency range in which spur tracking takes place.
Prerequisites for this command
●
Turn on spur tracking (CALCulate<n>:MARKer<m>:FUNCtion:SPTRacking[:
STATe]).
Suffix:
<n>
.
1..n
irrelevant
Common Analysis and Display Functions