Parameters:
<Distance> Defines the distance that the limit line moves.
Default unit: DB
Manual operation: See " Shift y " on page 181
CALCulate<n>:LIMit<li>:LOWer:SPACing <InterpolType>
This command selects linear or logarithmic interpolation for the calculation of a lower
limit line from one horizontal point to the next.
Suffix:
<n>
.
Window
<li> Limit line
Parameters:
<InterpolType> LINear | LOGarithmic
*RST: LIN
Manual operation: See " Y-Axis " on page 180
CALCulate<n>:LIMit<li>:NAME <Name>
This command selects a limit line that already exists or defines a name for a new limit
line.
Suffix:
<n>
.
Window
<li> Limit line
Parameters:
<Name> String containing the limit line name.
*RST: REM1 to REM8 for lines 1 to 8
Manual operation: See " Name " on page 180
CALCulate<n>:LIMit<li>:UNIT <Unit>
This command defines the unit of a limit line.
Suffix:
<n>
.
irrelevant
<li> Limit line
Parameters:
<Unit> If you select a dB-based unit for the limit line, the command
automatically turns the limit line into a relative limit line.
*RST: DBM
Manual operation: See " Y-Axis " on page 180
Common Analysis and Display Functions