1.SC Codes
117
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
Replace a connector between the Belt Centering Motor and TDRB (including
relay connectors).
Replace the Belt Centering Motor
Replace the TDRB.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC597
Motor Error
SC597-10
D
Tray 1 Lift Motor Error
SC597-11
D
Tray 2 Lift Motor Error
SC597-12
D
Rear Fence Drive Motor Error
SC597-50
D
Toner Pump Motor YM Error
SC597-51
D
Toner Pump Motor CK Error
SC597-52
D
Toner Pump Motor S Error
Detection period:100ms
SC is issued if error is detected 2 times consecutively.
Driver overheat protection operation
Driver excessive voltage protection operation
Motor shorted/layer shorted
Cycle the main power switch off/on.
Check that the connector is connected.
Replace the motor where SC occurred.
Replace the harnesses.
Replace the board.
Replace the following boards.
-10 to -12: PFB
-50 to -52: IOB
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC599-
00
D
Coolant Remaining Switch Error
The Coolant Remaining Switch detected the voltage more than the upper
threshold or less than the lower threshold.
When errors are detected 10 times consecutively during 1 second periods, it
is judged that an error has occurred and SC is issued.
Proper amount of liquid does not exist.
Connecter disconnected or broken.
IOB board defective.
Harness shorted.