1.SC Codes
117
Error Name/Error Condition/Major Cause/Solution
Replace a connector between the Belt Centering Motor and TDRB (including
relay connectors).
Replace the Belt Centering Motor
Replace the TDRB.
Error Name/Error Condition/Major Cause/Solution
Rear Fence Drive Motor Error
Toner Pump Motor YM Error
Toner Pump Motor CK Error
SC is issued if error is detected 2 times consecutively.
Driver overheat protection operation
Driver excessive voltage protection operation
Motor shorted/layer shorted
Cycle the main power switch off/on.
Check that the connector is connected.
Replace the motor where SC occurred.
Replace the harnesses.
Replace the board.
Replace the following boards.
-10 to -12: PFB
-50 to -52: IOB
Error Name/Error Condition/Major Cause/Solution
Coolant Remaining Switch Error
The Coolant Remaining Switch detected the voltage more than the upper
threshold or less than the lower threshold.
When errors are detected 10 times consecutively during 1 second periods, it
is judged that an error has occurred and SC is issued.
Proper amount of liquid does not exist.
Connecter disconnected or broken.
IOB board defective.
Harness shorted.