3.Troubleshooting: Paper Delivery Problems
481
[When repeatedly fails to feed]
Position the paper lift sensor bracket [B] so it reduces the gap [C] on the stay [A] while keeping an eye
on the scale on the upper part of the stay (1mm between lines).
Positioning it at a point at a distance of 0.5mm from the position before adjustment raises the
upper limit position about 0.8mm above the current state.
If there is no improvement by adjusting the stay position, this adjustment is not effective. Put
back the stay to the original position along with the marking [A].