1.SC Codes
179
Error Name/Error Condition/Major Cause/Solution
Motor driver detected an error. (SC from the first time)
Overcurrent to the motor.
Motor drive overheat
Connector disconnected
Replace the Main Board.
Replace the Entrance JG Motor
Replace the harness.
Re-connect the connector.
Replace the Entrance JG HP Sensor.
High Capacity Stacker
To recover from the error, check if the SC occurs (feed paper, open/close the doors, Input or Output
check). If the SC occurs again, do the follow steps. After each step, turn the power OFF then ON to
check if the SC occurs again.
Error Name/Error Condition/Major Cause/Solution
Stacker 1 (Upstream): Downstream device communication
Stacker 2 (Downstream): Downstream device communication
Downstream device break continued even after 10 sec passes.
Partner terminal does not break even 200 msec after the downstream device
starts to wait.
ATN without break is received in advance from the downstream device.
ST2 is received from the downstream device during receipt of ST1 frame, or
vice versa.
When the response (ACKn) to the frame sent to the downstream device is not
notified within the time limit (100 msec), frame sending is retried a maximum
of 3 times but there is still no responses acquired.
After connection with the downstream device, the downstream device breaks
again.
Interface cable (downstream device side) connector disconnected or broken.
Downstream device board defective, control board defective
Replace the control board.
Replace the downstream device board.
Replace the interface cable.
Error Name/Error Condition/Major Cause/Solution
Stacker 1 (Upstream): top door power supply error