1.SC Codes
180
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC731-03
D
Stacker 2 (Downstream): top door power supply error
Protection fuse blown when the power was being turned ON
Top door related motors defective
Top door related motors harness defective
1. Reconnect or replace the harnesses to the Top door switch.
2. Reconnect or replace the harnesses to the motors listed below.
Entrance Motor
Transport Motor
Proof Tray Exit Motor
Shift Tray JG Motor
Proof Tray JG Motor
Sub Jogger Motor
Main Jogger Fence Retraction Motor
3. Replace the controller board.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC730-04
D
Stacker 1 (Upstream): front door power supply error
SC731-04
D
Stacker 2 (Downstream): front door power supply error
Protection fuse blown when the power was being turned ON
Front door related motors defective
Front door related motors harness defective
1. Reconnect or replace the harnesses to the Front door switch.
2. Reconnect or replace the harnesses to the motors listed below.
Shift Motor
Shift Exit Motor
Main Jogger Front Fence Motor
Main Jogger Rear Fence Motor
LE Stopper Motor
Shutter Motor
3. Replace the controller board.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC730-10
D
Stacker 1 (Upstream): Entrance Motor Error
SC731-10
D
Stacker 2 (Downstream): Entrance Motor Error
Motor driver detected an error. (SC from the first time)
Motor defective
Motor driver overcurrent