1.SC Codes
371
Error Name/Error Condition/Major Cause/Solution
LCT3: Transport Motor Cooling Fan error
Cooling fan alarm “H (error)” is detected while the Transport Motor Cooling Fan
on the LCT3 is ON.
Transport Motor Cooling Fan on the LCT3 defective
Connector disconnected
Harness broken
PCB defective
Reconnect the connector.
Replace the Transport Motor Cooling Fan on the LCT3.
Replace the harness
Replace the PCB.
Error Name/Error Condition/Major Cause/Solution
LCT3: Connection configuration error (Bridge unit connection error)
The bridge unit is connected to LCT3.
The bridge unit is connected to LCT3 in triple LCT configuration.
Remove the bridge unit from the LCT3.
Error Name/Error Condition/Major Cause/Solution
LCT3: Connection configuration error (Multi bypass tray connection error)
The multi bypass tray is connected to LCT3.
The multi bypass tray is connected to LCT3.
Remove the multi bypass tray from the LCT3.
RPIP Interface Box
To recover from the error, check if the SC occurs (feed paper, open/close the doors, Input or Output
check). If the SC occurs again, do the follow steps. After each step, turn the power OFF then ON to
check if the SC occurs again.
Error Name/Error Condition/Major Cause/Solution
CRC error occurred 4 times when downloading data from EEPROM.
Last parameter writing was failed.
Board on the RPIP Interface Box defective
2. If the problem was not solved in Step 1, execute parameter writing again.
3. If the problem was not solved in Step 2, replace the board on the RPIP
Interface Box.