1.SC Codes
193
Service Call 750-790
SC700 (Engine: Peripherals)
Perfect Binder
To recover from the error, check if the SC occurs (feed paper, open/close the doors, Input or Output
check). If the SC occurs again, do the follow steps. After each step, turn the power OFF then ON to
check if the SC occurs again.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC750-01
D
Perfect Binder: Communication error with downstream peripheral
Break continued for 10 seconds or longer.
Anther STN was received during frame receipt.
No response even after resending 3 times.
Relay board defective, connector loose, broke, or defective
Reconnect the connector.
Replace the relay board.
Replace the harness.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC750-
10
D
Perfect Binder: Master-to-slave communication error 1
Master control board could not communicate with the slave control board for over
5 sec. and issued the communication alarm.
Master control board defective.
Slave Control Board defective
Connector loose, broken, defective
Reconnect the connector.
Replace the master control board.
Replace the slave control board.
Replace the harness.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC750-
11
D
Perfect Binder: Master-to-slave communication error 2
Slave control board could not communicate with the master control board for over
5 sec. and issued the communication alarm.
Master control board defective.
Slave Control Board defective
Connector loose, broken, defective
Reconnect the connector.
Replace the master control board.