1.SC Codes
370
Error Name/Error Condition/Major Cause/Solution
Harness broken
PCB defective
PSU1 defective
Reconnect the connector.
Replace the PSU Cooling Fan 1 on the LCT3.
Replace the harness
Replace the PCB
Replace the PSU2
Error Name/Error Condition/Major Cause/Solution
LCT3: PSU Cooling Fan 2 error
Cooling fan alarm “H (error)” is detected while the PSU Cooling Fan 2 on the
LCT3 is ON.
PSU Cooling Fan 2 on the LCT3 defective
Connector disconnected
Harness broken
PCB defective
PSU2 defective
Reconnect the connector.
Replace the PSU Cooling Fan 2 on the LCT3.
Replace the harness
Replace the PCB.
Replace the PSU2.
Error Name/Error Condition/Major Cause/Solution
LCT3: Transport Motor Cooling Fan error
Cooling fan alarm “H (error)” is detected while the Transport Motor Cooling Fan
on the LCT3 is ON.
Transport Motor Cooling Fan on the LCT3 defective
Connector disconnected
Harness broken
PCB defective
Reconnect the connector.
Replace the Transport Motor Cooling Fan on the LCT3.
Replace the harness
Replace the PCB.