1.SC Codes
124
Error Name/Error Condition/Major Cause/Solution
Reconnect the connectors.
Replace the harnesses.
Replace the motor/fan.
Replace the Controller Board of Buffer Pass Unit
Error Name/Error Condition/Major Cause/Solution
Downstream Device Communication Error (Buffer Pass Unit)
When communication has been established with downstream devices and
there is no response to the transmission command, not even after repeating
the command 3 times.
When communication has been established with upstream devices and the
transmission port level for the downstream devices does not turn to H level
(break release) within the time limit.
I/F cable (downstream device side) connector loose/disconnected
Board malfunction (Buffer Pass Unit or downstream device)
Replace I/F cable between Buffer Pass Unit and downstream device. Reset
connector.
Replace board (Buffer Pass Unit or downstream device)
Error Name/Error Condition/Major Cause/Solution
Communication error between the main machine and ADF connected with ASAP.
SC620-01: A BREAK was detected after a successful connection.
SC620-02: Communication timeout after a successful connection.
Details:
SC is issued when an error is detected after ADF connection was recognized at
power-on.
There will be no response either, if the ADF was not connected at power-on. In this
case, however, SC is not issued and functions that do not use the ADF (copying
from the exposure glass) are available.
ADF defective
IPU board defective
Electrical noise on the line