1.SC Codes
126
Error Name/Error Condition/Major Cause/Solution
3. Replace the controller board of the finisher.
Error Name/Error Condition/Major Cause/Solution
Vacuum Feed LCIT 1 Communication Error
Vacuum Feed LCIT 2 Communication Error (2
nd
connection)
Vacuum Feed LCIT 3 Communication Error (3
rd
connection)
When an error occurs during circuit connection.
When a communication error notice is received from UART.
Defective Main Board for Vacuum Feed LCIT
BCU defective
Connection between Vacuum Feed LCIT and main unit
defective/disconnected/shorted
Check if the SC occurs by turning the power OFF then ON. If the SC occurs again,
do the following steps. Check if the SC reoccurs by cycling the power after each
step.
1. Reconnect the cable between Vacuum Feed LCIT and main unit.
2. Reconnect the harness between BCU and LCIT.
3. Replace the harness between BCU and LCIT.
4. Replace the controller board of the LCIT.
5. Replace the BCU.
Error Name/Error Condition/Major Cause/Solution
TDCU Master Communication Error
TDCU Slave Communication Error
ASAP communication protocol error
The ASAP interface between engines has two systems: Master and Slave. The
error detection process is the same for both systems, but the SC number is
different.
Harness disconnected/loose
TDCU board error
BCU board error