1.SC Codes
153
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
issues immediately at 1st occurrence).
Motor defective
Harness short-circuit
Replace the motor/ Reconnect the connector.
Replace the harness.
Replace the Main Board.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC720-
05
D
PSU Cooling Fan Error
There was no LOCK detection signal issued from the fan motor (this SC issues
immediately at 1st occurrence).
PSU Cooling Fan Motor defective.
Connector disconnected
Drive circuit defective
Replace the PSU Cooling Fan Motor
Reconnect the connector.
Replace the harness.
Replace the Main Board.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC720-
10
D
Transport Motor Error 1 (Entrance, Straight-through)
DC motor drive software detected an error (this SC issues immediately at 1
st
occurrence).
Motor defective
Connecter disconnected
Overload
Encoder defective
Replace the Entrance Motor, reconnect the connectors.
Replace the harnesses.
Replace the Main Board.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC720-11
D
Transport Motor Error 2 (Junction Gate Feed)
Same as SC720-10
Same as SC720-10
Replace the Junction Gate Transport Motor