1.SC Codes
164
Error Name/Error Condition/Major Cause/Solution
When moving from the home position, home position was still detected after
specified number of pulses. (The first time: jam display, the second time: SC)
Connecter disconnected
Overload
Home position sensor defective
Replace the Booklet Stapler Side Fence Motor, reconnect the connector.
Replace the Booklet Stapler Side Fence HP Sensors (front, rear), reconnect
the connectors.
Replace the harnesses.
Replace the Main Board.
Resolve the mechanical failure for the booklet stack mechanism.
Error Name/Error Condition/Major Cause/Solution
Booklet Bottom Fence Motor Error
Replace the Booklet Bottom Fence Motor, reconnect the connector.
Replace the Booklet Stapler Bottom Fence HP Sensor, reconnect the
connector.
Replace the harnesses.
Replace the Main Board.
Resolve the mechanical failure for the booklet stack mechanism.
Error Name/Error Condition/Major Cause/Solution
Replace the Fold Plate Motor Error, reconnect the connector.
Replace the Fold Plate HP Sensor, reconnect the connector.
Replace the harnesses.
Replace the Main Board.
Resolve the mechanical failure for the booklet stack mechanism.
Error Name/Error Condition/Major Cause/Solution
Booklet Stapler Bottom Fence Motor Error