1.SC Codes
199
Error Name/Error Condition/Major Cause/Solution
Right lower spine plate fan overloaded, defective
Slave Control Board defective
Reconnect the connector.
Replace the right lower spin plate fan.
Replace the slave board.
Replace the motor harness.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Spine plate upper fan (front) lock error
Front upper spine plate fan overloaded, defective
Slave Control Board defective
Reconnect the connector.
Replace the front upper spine plate fan.
Replace the slave board.
Replace the motor harness.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Spine plate upper fan (right) lock error
Upper right spine plate fan overloaded, defective
Slave Control Board defective
Reconnect the connector.
Replace the upper right spine plate fan.
Replace the slave board.
Replace the motor harness.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Signature fan 2 (front) lock error
Front signature fan 2 failed to generate a lock signal within 12 sec., and signal
could be detected even after a re-try.
Front signature fan 2 overloaded, defective
Slave Control Board defective
Reconnect the connector.
Replace the front signature fan 2.
Replace the slave board.