1.SC Codes
32
Error Name/Error Condition/Major Cause/Solution
Charge FB Voltage Error (K) (1st)
Charge FB Voltage Error (C) (2st)
Charge FB Voltage Error (M) (3st)
Charge FB Voltage Error (Y) (4st)
Charge FB Voltage Error (S) (5st)
Charge FB Voltage Error (K) (5st)
Charge FB Voltage Error (S) (1st)
When the plotter is started with any line speed, the FB voltage is monitored 15
times at intervals of 20 ms, starting from 80 ms after the charging AC for operating
station turns ON.
If 0.3V or less is detected 15 times in a row, it lights the SC of the corresponding
color and judges the mechanism to be working.
High-voltage harness damaged or not connected correctly.
Charge roller or drum not installed
Charge bias power pack defective
Check the harness of charge bias power pack.
Reconnect /Replace the harness
Check the charge roller.
Set the charge roller if not set.
Check the drum.
Set the drum if not set.
Replace the charge bias power pack.
Error Name/Error Condition/Major Cause/Solution
Development Power Pack Output Error (1st)
Development Power Pack Output Error (C) (2st)
Development Power Pack Output Error (M) (3st)