1.SC Codes
368
Error Name/Error Condition/Major Cause/Solution
LCT2: Transport Motor Cooling Fan error
Cooling fan alarm “H (error)” is detected while the Transport Motor Cooling Fan
on the LCT2 is ON.
Transport Motor Cooling Fan on the LCT2 defective
Connector disconnected
Harness broken
PCB defective
Reconnect the connector.
Replace the Transport Motor Cooling Fan on the LCT2.
Replace the harness
Replace the PCB.
Error Name/Error Condition/Major Cause/Solution
LCT2: Transport Motor Cooling Fan error
Cooling fan alarm “H (error)” is detected while the Transport Motor Cooling Fan
on the LCT2 is ON.
Transport Motor Cooling Fan on the LCT2 defective
Connector disconnected
Harness broken
PCB defective
Reconnect the connector.
Replace the Transport Motor Cooling Fan on the LCT2.
Replace the harness
Replace the PCB.
Error Name/Error Condition/Major Cause/Solution
LCT2: Connection configuration error (LCT not connected)
LCT3 is detected while LCT2 is not installed.
The interface harness on the LCT1 broken
The interface harness on the LCT2 broken
PCB on the LCT1 defective
PCB on the LCT2 defective
Replace the interface harness on the LCT1
Replace the interface harness on the LCT2
Replace the PCB on the LCT1
Replace the PCB on the LCT2