1.SC Codes
54
Error Name/Error Condition/Major Cause/Solution
Error Name/Error Condition/Major Cause/Solution
PTR/ITB Cleaning Motor Error
Error at motor startup
A lock signal was not detected for 1 second or longer after 1 second has passed
from the motor START signal switching ON.
Error during motor running normally
A Lock signal was not detected for 1 second or longer during the motor START
signal being output.
PTR/ITB Cleaning Motor connector unplugged
Abnormal increase in paper transfer unit torque (such as overload due to
bearing lock)
Motor driver defective
PTR/ITB Cleaning Motor defective
Reconnect the motor connector
Remove the cause of overloading inside the paper transfer unit
Replace the motor driver
Replace the PTR/ITB Cleaning Motor.
Branch number list