1.SC Codes
65
Error Name/Error Condition/Major Cause/Solution
Paper or other obstacle blocking operation of pick-up solenoid
Cycle the main power switch off/on.
Error Name/Error Condition/Major Cause/Solution
A3 LCIT: 1st Tray (Top Tray): Upper Limit Detection Error
A3 LCIT: 2
nd
Tray (Middle Tray): Upper Limit Detection Error
A3 LCIT: 3
rd
Tray (Bottom Tray) : Upper Limit Detection Error
The following status was detected 3 times consecutively: The upper limit sensors
did not become on before pick-up solenoid is on at the start of tray initialization.
Pick-up Solenoid defective/ Connector disconnected
Upper Limit Sensor defective/ Connector disconnected
Related harness broken
Main Control Board defective
Check if the SC occurs by turning the power OFF then ON. If the SC occurs again,
do the following steps. Check if the SC reoccurs by cycling the power after each
step.
To check for any abnormalities in the sensor and motor solenoid, be sure to
perform an input check and output check for them as needed in addition to a
visual check.
Replace the Pick-up Solenoid.
Reconnect the Pick-up Solenoid connector.
Replace the Upper Limit Sensor
Reconnect the Upper Limit Sensor connector.
Replace the corresponding harness.
Replace the Main Control Board of the LCIT.
Error Name/Error Condition/Major Cause/Solution
A3 LCIT: 1st Tray (Top Tray): Upper Limit Detection Error
A3 LCIT: 2
nd
Tray (Middle Tray): Upper Limit Detection Error
A3 LCIT: 3
rd
Tray (Bottom Tray) : Upper Limit Detection Error
During Tray initialization, the tray bottom plate was lifted but the upper limit sensor