Idling time Shorter Longer
Fusing quality Lower Higher
1105*
Fusing Temperature Adjustment
Adjusts the target fusing temperature. Note that the thermistor is at the center of the hot
roller.
1105 1 Warm Up-Center [140 to 180 / 160 / 1°C/step]
1105 3 Standby-Center [140 to 160 / 150 / 1°C/step]
1105 5 Copying-Center [140 to 180 / 160 / 1°C/step]
1105 7 Low Level 2-Center [0 to 80 / 60 / 1°C/step]
1105 9 Thick-Center [140 to 185 / 165 / 1°C/step]
1106 Display Fusing
1106 1 Displays the fusing temperature.
1107*
Fusing Soft Start DFU
Adjusts the number of zero-cross cycles of the fusing lamp AC supply needed to bring the
fusing lamp power to 100% while bringing the lamp up to the standby temperature or while
copying. Increase this value if the machine is experiencing sudden power dropouts.
1107 1 Warm Up Soft Start [0 = 10 times / 1 = 20 times / 2 = 50 times]
1107 2 Other Soft Start [0 = 10 times / 1 = 20 times / 2 = 50 times / 3 = 1 time]
1107 3 Soft Stop Setting [0: No / 1: Yes]
1108* Set-Fusing Start [0 = 1s / 1 = 1.5s / 2 = 2s]
1108 1 Specifies the interval for fusing-temperature control.