EasyManua.ls Logo

Safran CORTEX CRT Quantum - IF Receiver in PCM Mode

Safran CORTEX CRT Quantum
346 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
COMMAND RANGING & TELEMETRY UNIT CORTEX
CRT QUANTUM USER'S MANUAL
Ref. DTU 100042
Is.Rev. 5.17
Date: Dec.
03, 2021Sept. 30, 2021
© Safran Data Systems
This document is the property of Safran Data Systems.
It cannot be duplicated or distributed without expressed written consent.
Page 43
3.3.2.3. IF Receiver in PCM Mode
Next table gives the acquisition and tracking Es/No thresholds according to the PLL bandwidth:
PLL BANDWIDTH (% SR)
BPSK WORST
CASE ES/NO (DB)
QPSK WORST
CASE ES/NO (DB)
OQPSK WORST
CASE ES/NO (DB)
0.01
-12
-3
-2
0.03
-8
-1
0
0.1
-7
1
2
0.3
-4
+3
+4
1
0
+5
+7
3
+3
+8
+10
Next table gives the acquisition and tracking Doppler rate threshold for the IF Receiver in direct PCM mode (no
sub-carrier):
DEMODULATION
WORST CASE DOPPLER RATE (HZ/S)
BPSK
Es/N0 > 10 dB: 0.02 x (Bit Rate x PLL Bandwidth)
2
, limited to 150
kHz/s
Es/N0 > 3 dB: 0.015 x (Bit Rate x PLL Bandwidth)
2
, limited to 150
kHz/s
XQPSK
Es/N0 > 10 dB: 0.006 x (Bit Rate x PLL Bandwidth)
2
, limited to 150
kHz/s
Es/N0 > 3 dB: 0.004 x (Bit Rate x PLL Bandwidth)
2
, limited to 150
kHz/s
Note: It must be checked that the programmed acquisition range and the expected maximum Doppler values are
consistent. The higher the acquisition range is, the longer will be the acquisition process.

Table of Contents