4.2.7.7.4. Change Time-tag Format
The default value of the time-tag format can be change with a TCP-IP Special Command (See STI 100013 -
§2.3.2.3.2). This value can be set in registry settings. The value will be taken into account at the next Cortex
software start-up.
Registry path: HKEY_LOCAL_MACHINE\SOFTWARE\In-snec\Cortex Station\Current Version
Keyword: UseNTP
Default setting at delivery: 0
Enter value between 0 (Code 0) and 5 (Code 5).
4.2.7.8. Telemetry Simulation
4.2.7.8.1. Access to Simulated TM Files
To modify the name and access path of the simulated telemetry files (TMS1 or TMS2 in File mode):
Registry path: HKEY_LOCAL_MACHINE\SOFTWARE\In-snec\CortexCRT\SetDefault\Preferences\TMSx
(x = TMS number)
Keyword: FileDir
Default setting at delivery: D:\ZDS\Data \CRT\Tms1\Ftms
D:\ZDS\Data \CRT\Tms2\Ftms
Extension _01.txt to _08.txt will be automatically appended to the selected name.
4.2.7.8.2. Swap G1 and G2 after Viterbi Encoding
To swap G1 and G2 after Viterbi encoder.
Registry path: HKEY_LOCAL_MACHINE\SOFTWARE\In-snec\CortexCRT\SetDefault\Preferences\TMSx
(x = TMS number)
Keyword: SwapG1G2
Default setting at delivery: 0 (G1 before G2)
Set the keyword to 1 to swap G1 and G2.