COMMAND RANGING & TELEMETRY UNIT CORTEX
CRT QUANTUM USER'S MANUAL
Ref. DTU 100042
Is.Rev. 5.17
Date: Dec.
03, 2021Sept. 30, 2021
This document is the property of Safran Data Systems.
It cannot be duplicated or distributed without expressed written consent.
4.2.7.7. Logging Data Storage & Data Time-tagging
4.2.7.7.1. Telemetry Time-Tagging
To modify the telemetry time-tagging (Time-tag the last or first bit of each TM frame/block).
Registry path: HKEY_LOCAL_MACHINE\SOFTWARE\In-snec\CortexCRT\SetDefault\Preferences\Tmux
(x = TM chain number)
Keyword: DateFrame
Default setting at delivery: 0
Enter 0 to time-tag the last bit of each telemetry frame or block; enter 1 to time-tag the first bit of each telemetry
frame or block, enter 2 to time-tag the first bit after the synchronization word
4.2.7.7.2. Logging Data Storage
To enable/disable logging data storage on the disk:
Registry path: HKEY_LOCAL_MACHINE\SOFTWARE\IN-SNEC\Cortex Station\SetDefault\Log
Keyword: Storage
Default setting at delivery: 0
Enter 0 to disable the storage. Enter 1 to enable the storage and automatically start it when SPS starts. Enter 2
to enable the storage without starting it when SPS starts.
To change the file name and access path:
Registry path: HKEY_LOCAL_MACHINE\SOFTWARE\IN-SNEC\Cortex Station\SetDefault\Log
Keyword: File Dir
Default setting at delivery: D:\ZDS\Data\Storage\Menu1\Log\Logging\LOG
The file extension for logging data is .log.
To change the file size:
Registry path: HKEY_LOCAL_MACHINE\SOFTWARE\IN-SNEC\Cortex Station\SetDefault\Log
Keyword: StoreSize
Default setting at delivery: 4096 (bytes)
To change the total maximum size:
Registry path: HKEY_LOCAL_MACHINE\SOFTWARE\IN-SNEC\Cortex Station\SetDefault\Log
Keyword: StoreTotal
Default setting at delivery: Not created
To enable/disable the 1st specific additional flow storage on the disk:
Registry path: HKEY_LOCAL_MACHINE\SOFTWARE\IN-SNEC\Cortex Station\SetDefault\Log\10
Keyword: EnableLog
Default setting at delivery: 1