2.3.4. Test Points Configuration
The Interconnection Panel has a number of analog and TTL test points, as described in the table above.
Depending on the software licenses, some of these test points may be disabled.
For instance, a standard CORTEX machine for station keeping operations (low bandwidth uplink and downlink),
the following « Video test points » only are available (see next table for more details):
VIDEO 1 & VIDEO 2 (analog out)
Sts Out/J25 to J28 (TTL, 50 Ω buffered)
Moreover, for a multi-mission machine with high data bandwidth requirements for the TMU, TMS or/and the TCU,
the available tests points are the full sets of test points (SET # 1 to SET # 4), for input & output from/to high
bandwidth functional units.