COMMAND RANGING & TELEMETRY UNIT CORTEX
CRT QUANTUM USER'S MANUAL
Ref. DTU 100042
Is.Rev. 5.17
Date: Dec.
03, 2021Sept. 30, 2021
This document is the property of Safran Data Systems.
It cannot be duplicated or distributed without expressed written consent.
4.2.7.3.7. Swap G1 and G2 before Viterbi Decoder
To swap G1 and G2 before Viterbi decoder.
Registry path: HKEY_LOCAL_MACHINE\SOFTWARE\In-snec\CortexCRT\SetDefault\Preferences\Tmux
(x = TM chain number)
Keyword: SwapG1G2
Default setting at delivery: 0 (G1 before G2) (or G1 on I, G2 on Q)
Set the keyword to 0 (G1 before G2) or 1 (swap G1 and G2)
4.2.7.3.8. Turbo Decoding Frame Synchronisation Word
To modify the default synchronization words specified for each rate (CCSDS 131.0-B-3)
Registry path: HKEY_LOCAL_MACHINE\SOFTWARE\In-snec\CortexCRT\SetDefault\Preferences\Tmux
(x = TM chain number)
Keyword: Asm_1_2
Default setting at delivery: 034776C7272895B0
Keyword: Asm_1_3
Default setting at delivery: 25D5C0CE8990F6C9461BF79C
Keyword: Asm_1_4
Default setting at delivery: 034776C7272895B0FCB88938D8D76A4F
Keyword: Asm_1_6
Default setting at delivery: 25D5C0CE8990F6C9461BF79CDA2A3F31766F0936B9E40863
Note : the frame synchronization word length is derived from the code rate.