4.2.7. SPS System Parameters Modification
SPS System parameters can be adjusted in the Windows registry. System parameters are high-level parameters
that cannot be changed without stopping the CORTEX SPS application software:
The following is a list of the value entries and sub keys referenced for CORTEX CRT Quantum product.
This is not intended to be a complete list of all value entries and sub keys for SAFRAN DATA SYSTEMS
applications in the Windows Registry. Please note that the entries in the Registry depend on the applications and
services installed on the CORTEX.
WARNING:
THE KEYS IN “SIGNAL PROCESSING” PATH CANNOT BE MODIFIED.
4.2.7.1. General Procedure for Changing a Registry Key
1. Click on Start / Run
2. Start the Windows registry editor (regedit)
3. Select referenced sub key path. Path root is [HKEY_LOCAL_MACHINE\SOFTWARE\In-snec\CortexCRT]
4. Double click on desired parameter, and change the value
5. Close the editor window
6. Stop and restart the CORTEX software
In multi-configuration mode, there is one set of parameters by menu selection. The menu ID is added to sub key
path. For example, the path for ‘Non Coherent / Coherent AGC’ parameters is
[HKEY_LOCAL_MACHINE\SOFTWARE\In-snec\CortexCRT\SetDefault]
for single configuration mode and for the menu one in the case of multi-configuration, and the path is
[HKEY_LOCAL_MACHINE\SOFTWARE\In-snec\CortexCRT\SetDefault2]
for the menu 2.