COMMAND RANGING & TELEMETRY UNIT CORTEX
CRT QUANTUM USER'S MANUAL
Ref. DTU 100042
Is.Rev. 5.17
Date: Dec.
03, 2021Sept. 30, 2021
© Safran Data Systems
This document is the property of Safran Data Systems.
It cannot be duplicated or distributed without expressed written consent.
Page 169
3.6.5. Measurement Time-Tagging
The time-tag in the ranging transaction response message corresponds to:
the first phase measurement performed on the first tone of the ranging sequence (INMARSAT and
LMCO standards),
the first « distance » calculation of the ranging message (ESA, ESA-like and USB tone standards,
ESA code standard).
Every measurement in the ranging transaction response message can be easily dated by simply adding to the
time-tag the appropriate number of time intervals separating two consecutive measurements.