EasyManua.ls Logo

Safran CORTEX CRT Quantum - Sweeping

Safran CORTEX CRT Quantum
346 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
COMMAND RANGING & TELEMETRY UNIT CORTEX
CRT QUANTUM USER'S MANUAL
Ref. DTU 100042
Is.Rev. 5.17
Date: Dec.
03, 2021Sept. 30, 2021
© Safran Data Systems
This document is the property of Safran Data Systems.
It cannot be duplicated or distributed without expressed written consent.
Page 131
Figure 70: "4 MHz" filter, -3 dB bandwidth: 8.46 MHz
3.4.5. Sweeping
See paragraph 3.5.3 for sweeping description.

Table of Contents