COMMAND RANGING & TELEMETRY UNIT CORTEX
CRT QUANTUM USER'S MANUAL
Ref. DTU 100042
Is.Rev. 5.17
Date: Dec.
03, 2021Sept. 30, 2021
This document is the property of Safran Data Systems.
It cannot be duplicated or distributed without expressed written consent.
5 5 00880ba6:0007e9c0 00883541:0003549c 19000 0
6 5 00883541:0004f9ac 008856f0:000d9b46 19000 0
7 2 01e282fe:000ec39d 0000009b:00044bf8 19000 3
8 1 01901f5c:0007d278 01903898:0004ae0f 19000 3
Each entry has the following fields:
File number (number “n” in the FTMUn file name).
Sequence number: it is incremented when a new recording session occurs for the TMU. All
the files used for a session have the same sequence number.
Time-tag of the first frame stored in the file: two words separated by a colon. Each word is
a 32-bit hexadecimal value.
Time-tag of the last frame stored in the file: two words separated by a colon. Each word is
a 32-bit hexadecimal value. For each time-tag, « First field » is the time in second (number
of seconds elapsed since January 1st, 0 :00 :00 :000 of current year), « Second field » is
the number of microseconds in the current second.
Bitrate configuration used when recording the frames
Time code configuration used when recording the frames.