COMMAND RANGING & TELEMETRY UNIT CORTEX
CRT QUANTUM USER'S MANUAL
Ref. DTU 100042
Is.Rev. 5.17
Date: Dec.
03, 2021Sept. 30, 2021
© Safran Data Systems
This document is the property of Safran Data Systems.
It cannot be duplicated or distributed without expressed written consent.
Page 163
Ambiguity resolution module :
Minor tones processing
f
tx_tone
IF
Receiver
Ranging Major Tone tracking
S
rx
(t) X
RG_rx
(t)
Major tone
synthesizer
Rone
(t)
Low pass &
decim. filter
PLL
filter
VCO
residual
(t)
Rough delay estimation :
N = number of 2
-rotations on the Major tone
Phase
accumulator
Rone
(t)
Rone
(t) =
Rone
(t)
mod2
+ 2
N
Figure 78: Doppler Aid Architecture
To configure the Doppler Aid module, The Doppler Rate Aid / Doppler Aid parameter is set to “Doppler”, and the
Carrier Doppler shift / Tone Doppler shift is set appropriately depending upon the satellite operation (Coherent vs
Non Coherent).

Table of Contents