Assuming that these parameters are: 500 kHz (tone frequency), 1 (no under-sampling), 4.3 s (integration time),
10 measurements on the tone and 1 Hz (loop bandwidth), the sequence duration is (the time to compute the tone
definition tables is not included):
Pre-transmission of the tone : 3.01 s
Integration time : 4.30 s
10 measurements on the tone (0.25 x 9) + Ts : 7.26 s
Total sequence duration : 14.57 seconds