COMMAND RANGING & TELEMETRY UNIT CORTEX
CRT QUANTUM USER'S MANUAL
Ref. DTU 100042
Is.Rev. 5.17
Date: Dec. 03, 2021Sept.
30, 2021
This document is the property of Safran Data Systems.
It cannot be duplicated or distributed without expressed written consent.
1.6.1. IF Reception
1.6.1.1. Analog Reception
1.6.1.1.1. IF Stages
IF input stages 3
IF input ports 2 per input stage (Nominal & Alternate)
Input bandwidth 50 to 90 MHz (- 3 dB bandwidth)
Input impedance 50 Ω
VSWR ≤ 1.25
Isolation between channels ≥ 80 dB
Aliasing rejection ≥ 80 dB
Maximum noise level - 20 dBm
(or No = - 96 dBm/Hz for 40 MHz noise bandwidth)
AGC range (CRT XL Quantum) - 15 to -105 dBm
AGC range (CRT eXplorer) - 15 to -120 dBm
AGC time constant 0.1, 1, 10, 100 or 1,000 ms
AGC mode Analog AGC : Non coherent
Digital AGC : Non coherent before carrier acquisition
then coherent (for PM and direct PCM, in a few Hz)
1.6.1.1.2. Auxiliary Inputs
Two Auxiliary input ports allow receiving baseband or IF signals for test purposes (example: TC demodulation at
IF):
Input ports 2
Input signal Baseband or IF signal
Input bandwidth At baseband : DC to 20 MHz
At IF : 0 to 90 MHz
Input signal level At baseband : 0.1 to 0.5 Vpp
At IF : 0 to - 20 dBm
AGC No
Input impedance 50 Ω