COMMAND RANGING & TELEMETRY UNIT CORTEX
CRT QUANTUM USER'S MANUAL
Ref. DTU 100042
Is.Rev. 5.17
Date: Dec. 03, 2021Sept.
30, 2021
© Safran Data Systems
This document is the property of Safran Data Systems.
It cannot be duplicated or distributed without expressed written consent.
Page 25
1.6.1.4.3. Frame Synchronization. Telemetry Storage
Frame synchronization Synchronization word size 8 to 32 bits
64, 96, 128, 192 for Turbo decoding
64 bits for LDPC 1/2, 2/3, 4/5
32 bits for LDPC 7/8
Frame size: 10 to 32,000 bytes
Synchronization strategy SYN (0 to 7 errors,
up to 64 errors for Turbo-decoding,
up to 64 errors for LDPC)
CTL (0 to 7 errors)
LTS (0 to 7 frames)
Bit slippage (0, 1 or 2 bits)
Synchronization word on I or Q Yes
Frame filtering 64-bit frame mask
CCSDS decoding transfer frame level:
Convolutional Viterbi : Yes
Soft decision : Yes
Bit error rate monitoring : Yes
Lock detector : Yes
Reed-Solomon : Yes
Turbo : Yes (CCSDS 131.0-B-3).
Scrambling : Yes
Interleave factor : Automatically programmed
Turbo decoding Rates 1/2, 1/3, 1/4 and 1/6
Output up to 5 Mb/s
Block length 1784, 3568, 7136 and 8920 bits
LDPC Decoding Rates 1/2, 2/3, 4/5, 7/8
Output up to 10 Mb/s
Block length 1024, 4096, 16384 bits for 1/2, 2/3, 4/5
7136 bits for 7/8
CCSDS decommutation CADU & VCDU : Yes
Telemetry storage on hard disk Time-tagged frames or blocks
Telemetry replay Yes (TM data re-modulation by the TMS in Replay mode)
Off-line telemetry transmission Yes (direct transfer to the LAN of stored telemetry)