Page 34
1.6.9.2. Reference Frequency
1.6.9.2.1. External Reference
Input port 2 ports. Programmable auto-selection
Frequency 5, 10 or 100 MHz sine or square
Acquisition range > 5 kHz for 100 MHz, > 500 Hz for 10 MHz, > 250 Hz for 5 MHz
Impedance 50
Level 0.5 to 5 Vpp
DC max. = ± 4 V
1.6.9.2.2. Internal Reference
Frequency 10 MHz
Frequency stability ≤ ± 5 ppm ageing first year
± 2 ppm ageing following years
≤ ± 15 ppm vs temperature variations (10° to 40°)
Frequency adjustment No (factory configured)