Page 36
1.6.10.3.Synthesizer Specifications
RF phase noise Guaranteed values
- 70dBc/Hz @ 100 Hz / - 90dBc/Hz @ 1 KHz / - 95dBc/Hz @ 10 kHz /
- 95dBc/Hz @ 100 kHz / - 110dBc/Hz @ 1 MHz
Typical value
- 80dBc/Hz @ 100 Hz / - 95dBc/Hz @ 1 KHz / - 100dBc/Hz @ 10 kHz /
- 100dBc/Hz @ 100 kHz / - 120dBc/Hz @ 1 MHz
Frequency Tuning < 0.1 µHz with CRT or 5 Mhz steps alone
1.6.11. Mechanical – Environment
Industrial PC chassis Height: 4 rack spaces for 4U chassis or 2 rack spaces for 2U chassis
Width : 19 inches
Depth : 550 mm for 4U chassis or 500mm for 2U chassis
Weight 25 kg (configuration dependent)
Built-in ventilation unit
Operating temperature + 10 °C to + 40 °C
Storage temperature - 20 °C to + 60 °C
Relative humidity 40 % to 95 % non-condensing
Temperature alarms Front panel LED (model dependent) & TCP-IP status
Front panel color RAL 5023
1.6.12. Supply
Power Supply Voltage 100 - 240 VAC (-10%, +6%)
Frequency 50 / 60 Hz
Nominal consumption 3.3 A 1.4 A
Maximum consumption 9.0 A 4.5 A
Redundant power supply

Table of Contents